Behrenbeck / Sowton / Fontaine | Cardiac Pacemakers | Buch | 978-3-662-06212-8 | www.sack.de

Buch, Englisch, 323 Seiten, Format (B × H): 170 mm x 244 mm, Gewicht: 581 g

Behrenbeck / Sowton / Fontaine

Cardiac Pacemakers

Diagnostic Options · Dual Chamber Pacing Rate Responsive Pacing · Antitachycardia Pacing
Softcover Nachdruck of the original 1. Auflage 1985
ISBN: 978-3-662-06212-8
Verlag: Springer

Diagnostic Options · Dual Chamber Pacing Rate Responsive Pacing · Antitachycardia Pacing

Buch, Englisch, 323 Seiten, Format (B × H): 170 mm x 244 mm, Gewicht: 581 g

ISBN: 978-3-662-06212-8
Verlag: Springer


Springer Book Archives

Behrenbeck / Sowton / Fontaine Cardiac Pacemakers jetzt bestellen!

Zielgruppe


Professional/practitioner

Weitere Infos & Material


The “Philosophy” of the Diagnostic Pacemaker.- Comparison of Different Pacemakers with Holter Functions.- Clinical Evaluation of a Diagnostic Pulse Generator (DPG) with Special Analysis Functions in Pacemaker Patient Follow-up.- Clinical Importance of the Analysis Functions of a Multiprogrammable Pacemaker.- Determination of the Endocardial Signal Amplitude in Single-Chamber Demand Pacemakers: Comparison of two Measurement Methods.- Progress in Holter Monitoring Towards an Implantable System.- Memory Technology and Implantable Holter Systems.- Value and Limitations of the Holter Functions of a Single Chamber Diagnostic Pacemaker.- Pacemaker Holter ECG: Value and Limitations in Follow-up of Pacemaker Patients.- Prevention and Improved Detection of Pacemaker Dysfunctions.- Physiological Pacing and Biological Adjustment.- Rate Responsive Pacing — Initial Experience with the QT (TX/Quintech) and Biorate Pacemakers.- Problems with the Slope Adjustment and Rate Adaption in Rate Responsive Pacemakers: Oscillation Phenomena and Sudden Rate Jumps.- Comparison of VVI and QT-Related Rate Adaptive Pacing — Pulmonary Artery Pressure, Pulmonary Capillary Pressure, Heart Rate and Cardiac Output.- Clinical Experience with the Respiratory Rate Responsive Pacemaker.- Respiration Dependent Pacemakers.- Results with the SO2-Controlled Pacemaker.- Preliminary Clinical Results with a New Software-Controlled DDD Pacemaker.- DDI Mode: A New Stimulation Mode in the Therapy of Pacesetting Disorders.- A New Generation of Dual Chamber Pacemakers with Automatic In-Built Rhythm Recognition Capabilities.- Left Ventricular Function During VVI and DVI Pacing at Different Rates as Assessed by M-Mode and Two-Dimensional Echocardiography, Gated Single Photon Emission Computerized Tomography(GASPECT) and Thermodilution.- New Aspects on the Pathogenesis of Ischemia-Induced Ventricular Arrhythmias.- Pre-Implantation Evaluation of Candidates for an Antitachycardia Pacemaker.- Subthreshold Burst Pacing.- Tachycardia Recognition by Implantable Devices.- The Use of the Ventricular Paced Evoked Response in Antitachycardia Pacemaker Design.- Detections and Discrimination of Supraventricular Tachycardia from Sinus Tachycardia of Overlapping Cycle Lengths.- A Description of Reliable Pacemaker Holter Functions in the Future Antitachycardia Pacemaker.- Antitachycardia Pacemakers — an Overview.- Value and Limitations of the DPG-1 Pacemaker Anti-Arrthythmic Functions.- Use of Flywheel, Automatic Underdrive and Dynamic Overdrive in Atrial Pacers.- Description and Efficacy of PASAR Algorithms.- Clinical Results with the Tachylog P43.- The Antitachycardia Capabilities of Symbios.- Clinical Long-Term Experiences with High Rate Antitachycardia Stimulation (Cybertach 60).- Endo-Epicardial Cardioversion-Defibrillation for Termination of Drug-Refractory Ventricular Tachyarrhythmias.- Single-Beat Stimulation and Train of Stimuli Method for Prevention of Reentrant Tachycardia.- Hemodynamic and Antiectopic Effects of Long-term Dynamic Overdrive Pacing in Implanted VVI Pacemakers.- Arrhythmias induced by Antitachycardial Pacing.- The Surgical Approach to Tachycardias.- Author Index.



Ihre Fragen, Wünsche oder Anmerkungen
Vorname*
Nachname*
Ihre E-Mail-Adresse*
Kundennr.
Ihre Nachricht*
Lediglich mit * gekennzeichnete Felder sind Pflichtfelder.
Wenn Sie die im Kontaktformular eingegebenen Daten durch Klick auf den nachfolgenden Button übersenden, erklären Sie sich damit einverstanden, dass wir Ihr Angaben für die Beantwortung Ihrer Anfrage verwenden. Selbstverständlich werden Ihre Daten vertraulich behandelt und nicht an Dritte weitergegeben. Sie können der Verwendung Ihrer Daten jederzeit widersprechen. Das Datenhandling bei Sack Fachmedien erklären wir Ihnen in unserer Datenschutzerklärung.