Bossuyt / Deconinck | Amplitude/phase patterns in dynamic scintigraphic imaging | Buch | 978-94-009-6011-4 | www.sack.de

Buch, Englisch, 168 Seiten, Format (B × H): 155 mm x 235 mm, Gewicht: 271 g

Reihe: Developments in Nuclear Medicine

Bossuyt / Deconinck

Amplitude/phase patterns in dynamic scintigraphic imaging


Erscheinungsjahr 2011
ISBN: 978-94-009-6011-4
Verlag: Springer

Buch, Englisch, 168 Seiten, Format (B × H): 155 mm x 235 mm, Gewicht: 271 g

Reihe: Developments in Nuclear Medicine

ISBN: 978-94-009-6011-4
Verlag: Springer


Conventional nuelear medieine proeedures study the dis tribution of radiolabelled eompounds (radiopharmaeeutieals) in the body under physiologieal as well as under pathologieal eonditions. Beeause of their ability to visua lise and to quantify the distribution of radiopharmaeeuti eals within the body by means of external deteetors, nuelear medieine teehniques are basieally non invasive and funetion oriented. The spatial variation of the traeer distribution in the field of view, or the ehange in distribution during a time interval are interpreted as representing speeifie phy siologie or pathophysiologie processes. As eompared to other diagnostie imaging teehniques, the spatial resolution of seintigraphie images is rather poor, their temporal resolu tion is good. Faetors that will therefore determine the ultimate diag nostie value of a seintigraphie study inelude 1. The speeifieity of the labelled eompounds for the process under study, 2. The resolution in time and space of the instrumentation, and its ability of measuring quantitatively tissue aetivity eoneentrations, 3. The formulation of physiologieal or pathophysiologieal models from whieh the distribution of the traeer ean be predieted. 2 While interpreting nuclear medicine data, the interrelations between these factors should permanently remain under consi deration. The generalised use of minicomputers has resulted in major advances in information processing in nuclear medicine imaging procedures. Central to this is image digitisation.

Bossuyt / Deconinck Amplitude/phase patterns in dynamic scintigraphic imaging jetzt bestellen!

Zielgruppe


Research

Weitere Infos & Material


Content.- 1. The temporal Fourier transform as a general approach to functional isotopic imaging.- 2. Amplitude/phase imaging of transient phenomena: superior cavography.- 3. Regional breathing patterns studied by dynamic transmission scintigraphy and the temporal Fourier transform.- 4. Amplitude/phase images as a temporal condensate of the averaged cardiac cycle.- 5. Clinical evaluation of amplitude/phase analysis for the assessment of regional wall motion disturbances.- 6. Non-invasive assessment of the proximal stenoses of the main coronary arteries by means of exercise radionuclide ventriculography.- 7. Functional dissimilarity between anterior and posterior ventricular walls during acute myocardial infarction.- 8. Scintigraphic visualisation of the effect of conduction disturbances on the mechanical events of the cardiac cycle.- 9. Parametric imaging and temporal contrast enhancement for the visualisation of time patterns.- 10. Radionuclide indices of cardiac function related to structural ventricular disorders.- Conclusions.- Color plates.- Index of Subjects.



Ihre Fragen, Wünsche oder Anmerkungen
Vorname*
Nachname*
Ihre E-Mail-Adresse*
Kundennr.
Ihre Nachricht*
Lediglich mit * gekennzeichnete Felder sind Pflichtfelder.
Wenn Sie die im Kontaktformular eingegebenen Daten durch Klick auf den nachfolgenden Button übersenden, erklären Sie sich damit einverstanden, dass wir Ihr Angaben für die Beantwortung Ihrer Anfrage verwenden. Selbstverständlich werden Ihre Daten vertraulich behandelt und nicht an Dritte weitergegeben. Sie können der Verwendung Ihrer Daten jederzeit widersprechen. Das Datenhandling bei Sack Fachmedien erklären wir Ihnen in unserer Datenschutzerklärung.