Cabrera | Development of 15 Micron Cutoff Wavelength HgCdTe Detector Arrays for Astronomy | Buch | 978-3-030-54240-5 | sack.de

Buch, Englisch, 121 Seiten, HC gerader Rücken kaschiert, Format (B × H): 160 mm x 241 mm, Gewicht: 383 g

Reihe: Springer Theses

Cabrera

Development of 15 Micron Cutoff Wavelength HgCdTe Detector Arrays for Astronomy

Buch, Englisch, 121 Seiten, HC gerader Rücken kaschiert, Format (B × H): 160 mm x 241 mm, Gewicht: 383 g

Reihe: Springer Theses

ISBN: 978-3-030-54240-5
Verlag: Springer International Publishing


This thesis describes advances in the understanding of HgCdTe detectors. While long wave (15 µm) infrared detectors HgCdTe detectors have been developed for military use under high background irradiance, these arrays had not previously been developed for astronomical use where the background irradiance is a billion times smaller. The main pitfall in developing such arrays for astronomy is the pixel dark current which plagues long wave HgCdTe. The author details work on the success of shorter wavelength development at Teledyne Imaging Sensors, carefully modeling the dark current–reverse bias voltage curves of their 10 µm devices at a temperature of 30K, as well as the dark current–temperature curves at several reverse biases, including 250 mV. By projecting first to 13 and then 15 µm HgCdTe growth, values of fundamental properties of the material that would minimize tunneling dark currents were determined through careful modeling of the dark current-reverse bias voltage curves, as well as the dark current-temperature curves. This analysis was borne out in the 13 µm parts produced by Teledyne, and then further honed to produce the necessary parameters for the 15 µm growth. The resulting 13 µm arrays are being considered by a number of ground-based astronomy research groups.
Cabrera Development of 15 Micron Cutoff Wavelength HgCdTe Detector Arrays for Astronomy jetzt bestellen!

Zielgruppe


Research


Autoren/Hrsg.


Weitere Infos & Material


Chapter1: Introduction.- Chapter2: Test and Data Acquisition Setup.- Chapter3: Dark Current Theory.- Chapter4: Array Characterization.- Chapter5: Phase I Results: 13 m Cuto Wavelength Devices.- Chapter6: Phase II Results: 15 m Cuto Wavelength Devices.- Chapter7: Conclusions and Future Work.


Mario Cabrera received his PhD from the University of Rochester in 2020.


Ihre Fragen, Wünsche oder Anmerkungen
Vorname*
Nachname*
Ihre E-Mail-Adresse*
Kundennr.
Ihre Nachricht*
Lediglich mit * gekennzeichnete Felder sind Pflichtfelder.
Wenn Sie die im Kontaktformular eingegebenen Daten durch Klick auf den nachfolgenden Button übersenden, erklären Sie sich damit einverstanden, dass wir Ihr Angaben für die Beantwortung Ihrer Anfrage verwenden. Selbstverständlich werden Ihre Daten vertraulich behandelt und nicht an Dritte weitergegeben. Sie können der Verwendung Ihrer Daten jederzeit widersprechen. Das Datenhandling bei Sack Fachmedien erklären wir Ihnen in unserer Datenschutzerklärung.