Higgins | The Implantable Cardioverter Defibrillator | Buch | 978-0-87993-663-1 | www.sack.de

Buch, Englisch, 104 Seiten, Format (B × H): 120 mm x 202 mm, Gewicht: 134 g

Higgins

The Implantable Cardioverter Defibrillator


1. Auflage 1998
ISBN: 978-0-87993-663-1
Verlag: Wiley-Blackwell

Buch, Englisch, 104 Seiten, Format (B × H): 120 mm x 202 mm, Gewicht: 134 g

ISBN: 978-0-87993-663-1
Verlag: Wiley-Blackwell


Finally, a comprehensive yet practical video/text guide on the techniques and clinical considerations related to ICD insertion. Dr. Higgins discusses important related areas too, such as patient selection, O.R. preparation, surgical techniques of lead access, generator implantation and post-operative management, including complications. The 30-minute video presents several different approaches to venous access, proper generator positioning, both subcutaneous and submuscular, as well as pectoral and abdominal sites.

As a leading researcher in ICD therapy, Dr. Higgins has participated in over 1,000 such procedures. He was recently one of the principal investigators in the Multicenter Automated Defibrillator Implantation Trial (MADIT), a blind test in which ICD therapy was associated with a 56% reduction in two-year mortality versus those treated
with conventional medical therapy.

More detailed and case management oriented than any proprietary ICD manufacturer 'in-house' video, The Implantable Cardioverter Defibrillator: A Videotape and Manual is a superb training tool from a world-class expert and ICD pioneer.

Higgins The Implantable Cardioverter Defibrillator jetzt bestellen!

Autoren/Hrsg.


Weitere Infos & Material


Preface.

Arthur J. Moss, MD.

1. An Introduction to ICDs.

• History.

• Who Should Implant ICDs?.

• An Introduction to the Video.

2. Patient Selection; Site Selection.

• Indications.

• Risk Factors for ICD Surgery.

• Risks of ICD Surgery.

• ICD Site Selection.

• Preparation of the Patient.

3. The Logistics of ICD Insertion.

• Setting Up an ICD Operating Room.

• Surgical Instruments.

• Staffing for ICD Surgery: Physicians and Support Personnel.

• Surgical Support and Consultation.

• Anesthesia: Agents and Who Should Administer Them.

• Supplies.

4. Venous Access and Lead Positioning.

• General Considerations.

• The Subclavian Venipuncture Technique.

• The Cephalic Vein Cutdown Technique.

5. ICD Lead Positioning and Testing.

• ICD Lead Advancement.

• DFT Testing.

• Optimal Lead Placement: The Endotak-DSP Study.

6. The Subcutaneous Pectoral Approach.

• Advantages of the Subcutaneous Approach.

• Disadvantages of Subcutaneous Pectoral Approach.

• General Surgical Issues.

• Antibiotic Usage.

7. Submuscular Pectoral Approach.

• Anatomy of the Subpectoral Region.

• Anterior Approach.

• Lateral (Anterior Axillary) Approach.

• Multilayer Closure.

8. Abdominal Generator Techniques.

• Anatomy of the Abdominal Wall Region.

• Subcutaneous Abdominal ICD Insertion.

• Submuscular Abdominal ICD Insertion.

• General Surgical Principles for Abdominal ICD Placement.

• Techniques for ICD Lead Tunneling.

9. Generator Change Procedures.

• Pocket Revision.

• Lead Evaluation and Repair.

• Pocket Closure.

10. Dressing Care and Postprocedure Management.

• Dressing Options.

• Immediate Postprocedure Care.

• Predischarge Orders.

• Postoperative Patient Education.

• ICD Support Groups.

11. Management of Complications.

• Problems Encountered at Implant.

• Problems Encountered in the Immediate Postimplant Period.

• Chronic Lead and Device Complications


As a leading researcher in ICD therapy, Dr. Higgins has participated in over 1,000 such procedures. He was recently one of the principal investigators in the Multicenter Automated Defibrillator Implantation Trial (MADIT), a randomized trial in which ICD therapy was associated with a 56% reduction in two-year mortality versus those treated
with conventional medical therapy.



Ihre Fragen, Wünsche oder Anmerkungen
Vorname*
Nachname*
Ihre E-Mail-Adresse*
Kundennr.
Ihre Nachricht*
Lediglich mit * gekennzeichnete Felder sind Pflichtfelder.
Wenn Sie die im Kontaktformular eingegebenen Daten durch Klick auf den nachfolgenden Button übersenden, erklären Sie sich damit einverstanden, dass wir Ihr Angaben für die Beantwortung Ihrer Anfrage verwenden. Selbstverständlich werden Ihre Daten vertraulich behandelt und nicht an Dritte weitergegeben. Sie können der Verwendung Ihrer Daten jederzeit widersprechen. Das Datenhandling bei Sack Fachmedien erklären wir Ihnen in unserer Datenschutzerklärung.