Warm Air Heating describes the underlying principles of heating by warm air and illustrates how these are carried into practice. This book discusses the heat transmission through building construction, warm air heating classifications, computation of heat requirements, and fan laws and definitions. The air filter performance determinants, reactivation heat requirement versus adsorption capacity of sorbsil silica gel, and erection of ductwork are also elaborated. This text likewise covers the field measurement of sound, theory of vibration isolation, application of thermal insulation, and behavior of a heated air jet. Other topics include the duct layouts, electrically operated controls, measurement of air flow, and warm air heating using high temperature heating media. The off-peak electric warm air heaters and industrial applications of warm air heating are also deliberated. This publication is recommended for students, designers, and installers of warm air heating systems.

Kut / Billington / Ower Warm Air Heating jetzt bestellen!

Weitere Infos & Material


1;Front Cover;1
2;Warm Air Heating;4
3;Copyright Page;5
4;Table of Contents;6
5;LIST OF TABLES;8
6;LIST OF ILLUSTRATIONS;10
7;PREFACE;14
8;EDITORS' PREFACE;18
9;ACKNOWLEDGEMENTS;20
10;CHAPTER 1.
THERMAL COMFORT AND HEAT TRANSFER;22
10.1;HEAT TRANSFER;28
10.2;THERMAL CONDUCTIVITY;28
10.3;HEAT TRANSMISSION THROUGH BUILDING CONSTRUCTION;29
10.4;REFERENCES;35
11;CHAPTER 2. PROPERTIES OF AIR;36
11.1;REFERENCES;48
12;CHAPTER 3. WARM AIR HEATING SYSTEM CLASSIFICATIONS;49
12.1;PRIMARY HEAT SOURCE;49
12.2;FUELS;50
12.3;REFERENCES;56
13;CHAPTER 4. BASIC DESIGN CONSIDERATIONS;57
13.1;GENERAL CONSIDERATIONS;57
13.2;DETAILED CONSIDERATIONS;57
13.3;COMPUTATION OF HEAT REQUIREMENTS;58
13.4;REFERENCES;70
14;CHAPTER 5. AIR HEATERS;71
14.1;HEAT SOURCE;72
14.2;HEAT EXCHANGER OR AIR HEATER;72
14.3;REFERENCES;91
15;CHAPTER 6. FANS;92
15.1;FAN LAWS AND DEFINITIONS;92
15.2;CENTRIFUGAL FANS;94
15.3;AXIAL FLOW FANS;96
15.4;PROPELLER FANS;103
15.5;CROSS-FLOW (TANGENTIAL) FANS;104
15.6;MIXED-FLOW FANS (IN-LINE CENTRIFUGAL FANS);105
15.7;FAN POWER;105
15.8;EXAMPLES;106
15.9;FAN DRIVES;108
15.10;LUBRICATION;108
15.11;FAN TECHNICAL INFORMATION;109
15.12;REFERENCES;109
16;CHAPTER 7. AIR FILTERS;110
16.1;PARTICLE SIZE;110
16.2;NATURE OF IMPURITIES;110
16.3;AIR FILTER PERFORMANCE DETERMINANTS;113
16.4;INFLAMMABILITY OF DUSTS;114
16.5;DESCRIPTION OF AIR FILTERS;115
16.6;FILTER MAINTENANCE;136
16.7;REFERENCES;137
17;CHAPTER 8.HUMIDITY CONTROL;138
17.1;EXAMPLE;142
17.2;INDUSTRIAL HUMIDIFICATION;145
17.3;HUMIDIFIERS;147
17.4;WATER TREATMENT;154
17.5;DEHUMIDIFIERS;156
17.6;QUANTITY OF (SORBSIL BRAND) SILICA GEL REQUIRED;158
17.7;REACTIVATING (SORBSIL) SILICA GEL;163
17.8;REACTIVATION HEAT REQUIREMENT VERSUS ADSORPTION
CAPACITY OF SORBSIL SILICA GEL;164
17.9;CALCULATION OF BED RELATIVE HUMIDITY;165
17.10;REFERENCES;167
18;CHAPTER 9. AIR DUCTS;168
18.1;SHEET METAL DUCTS;168
18.2;MASS PRODUCTION;182
18.3;DUCTS—OTHER THAN STEEL;184
18.4;ERECTION OF DUCTWORK;191
18.5;STRUCTURE-INTEGRATED AIR DISTRIBUTION;193
18.6;REFERENCES;197
19;CHAPTER 10. SOUND ATTENUATION;198
19.1;SOUND ATTENUATION;198
19.2;DEFINITIONS;199
19.3;FIELD MEASUREMENT OF SOUND;203
19.4;SOUND ABSORPTION;205
19.5;FANS—SOUND LEVEL ANALYSIS;210
19.6;DUCT-BORNE VENTILATION NOISE;213
19.7;AERODYNAMIC NOISE REGENERATION;215
19.8;CRITERIA FOR NOISE CONTROL;219
19.9;REFERENCES;223
20;CHAPTER 11. ISOLATION OF VIBRATION;224
20.1;1. Machine Weight and Weight Distribution;225
20.2;2. Machine Speed or Speeds;225
20.3;3. Machine Dynamic Type;226
20.4;4. Isolator Characteristics;226
20.5;5. Supporting Structure Characteristics;227
20.6;6. Permissible Motion of the Machine;227
20.7;7. Permissible Motion of the Supporting Structure;227
20.8;THEORY OF VIBRATION ISOLATION;227
20.9;REFERENCE;231
21;CHAPTER 12. THERMAL INSULATION;232
21.1;PRINCIPLES OF INSULATION;232
21.2;DESCRIPTION OF INSULATING MATERIALS;235
21.3;FIRE RETARDANTS;240
21.4;THE APPLICATION OF THERMAL INSULATION;241
21.5;CHOICE OF INSULATION METHOD;242
21.6;CALCULATION OF HEAT FLOW THROUGH THERMAL INSULATION;244
21.7;DETERMINATION OF THE ECONOMIC THICKNESS;245
21.8;REFERENCES;247
22;CHAPTER 13. AIR DISTRIBUTION;248
22.1;BEHAVIOUR OF A HEATED AIR JET;252
22.2;EXAMPLES OF AIR DISTRIBUTION EQUIPMENT;258
22.3;REFERENCES;268
23;CHAPTER 14. DUCT DESIGN;269
23.1;AIR FLOW IN DUCTS;269
23.2;DUCT SIZING;270
23.3;DUCT DESIGN METHODS;274
23.4;SYSTEM RESISTANCE;288
23.5;COMPARISON OF DUCT-SIZING METHODS;295
23.6;DUCT SIZING—FURTHER EXAMPLES;299
23.7;EXTRACT VENTILATION;300
23.8;REFERENCES;301
24;CHAPTER 15. DUCT LAYOUTS;302
25;CHAPTER 16. WARM AIR CURTAINS;308
25.1;DESIGN DATA;310
25.2;EXTRACT OPENING;314
25.3;OUTPUT CONTROL;315
25.4;EFFECT OF BUILDING CONSTRUCTION;315
25.5;SIMPLIFIED AIR CURTAIN;316
25.6;PACKAGED DOOR HEATER;316
25.7;SUMMARY OF RECOMMENDATIONS;318
25.8;REFERENCES;319
26;CHAPTER 17. AUTOMATIC CONTROLS;320
26.1;BASIC INFORMATION;320
26.2;SELF-ACTING CONTROLS;321
26.3;ELECTRICALLY OPERATED CONTROLS;325
26.4;PNEUMATIC CONTROLS;335
26.5;REFERENCES;347
27;CHAPTER 18. MEASUREMENT OF AIR FLOW;348
27.1;PITOT-STATIC TUBE;348
27.2;VANE ANEMOMETER;350
27.3;THERMOANEMOMETER;352
27.4;VELOMETER;353
27.5;REFERENCE;355
28;CHAPTER 19. WARM AIR HEATING USING HIGH TEMPERATURE HEATING MEDIA;356
28.1;TETRA-SILICATES;364
28.2;REFERENCES;366
29;CHAPTER 20. SELF-CONTAINED ASSEMBLIES;367
29.1;OIL-FIRED AIR HEATERS;367
29.2;GAS-FIRED AIR HEATERS;375
29.3;OFF-PEAK ELECTRIC WARM AIR HEATERS;380
29.4;SOLID-FUEL-FIRED HEATERS;383
29.5;REFERENCES;388
30;CHAPTER 21. INDUSTRIAL APPLICATIONS;389
30.1;PAINT SPRAY SHOPS;389
30.2;WOODWORKING FACTORIES;394
30.3;FOUNDRIES;396
30.4;VENTILATION WITH CANOPY HOODS;399
30.5;BROILER AND POULTRY HOUSES;403
30.6;REFERENCES;412
31;INDEX;414



Ihre Fragen, Wünsche oder Anmerkungen
Vorname*
Nachname*
Ihre E-Mail-Adresse*
Kundennr.
Ihre Nachricht*
Lediglich mit * gekennzeichnete Felder sind Pflichtfelder.
Wenn Sie die im Kontaktformular eingegebenen Daten durch Klick auf den nachfolgenden Button übersenden, erklären Sie sich damit einverstanden, dass wir Ihr Angaben für die Beantwortung Ihrer Anfrage verwenden. Selbstverständlich werden Ihre Daten vertraulich behandelt und nicht an Dritte weitergegeben. Sie können der Verwendung Ihrer Daten jederzeit widersprechen. Das Datenhandling bei Sack Fachmedien erklären wir Ihnen in unserer Datenschutzerklärung.