Buch, Englisch, 160 Seiten, Format (B × H): 154 mm x 229 mm, Gewicht: 285 g
ISBN: 978-0-470-02516-1
Verlag: Wiley
This text presents the information needed to design a successful quantitative analysis using mass spectrometric techniques currently available and widely employed. It is devoted to the researchers of different areas, who use mass spectrometry as a detector suitable for the measurements of their interest. - An essential book for the practicing mass spectroscopist
- A genuine 'how-to' text for the practitioner focusing on quantification rather than instrumental design and techniques
- Up-to-date structured text describing methods, experimental strategy, capabilities and limitations, with data analysis and interpretation
- Brings together material widely dispersed in the pertinent literature into one unique source
- Internationally recognized group of authors
Autoren/Hrsg.
Fachgebiete
Weitere Infos & Material
Preface ix
Acknowledgements xi
Introduction xiii
1 What Instrumental Approaches are Available 1
1.1 Ion Sources 1
1.1.1 Electron Ionization 3
1.1.2 Chemical Ionization 4
1.1.3 Atmospheric Pressure Chemical Ionization 6
1.1.4 Electrospray Ionization 8
1.1.5 Atmospheric Pressure Photoionization 11
1.1.6 Matrix-assisted Laser Desorption/Ionization 12
1.2 Mass Analysers 14
1.2.1 Mass Resolution 14
1.2.2 Sector Analysers 15
1.2.3 Quadrupole Analysers 19
1.2.4 Time-of-flight 25
1.3 GC/MS 27
1.3.1 Total Ion Current (TIC) Chromatogram 27
1.3.2 Reconstructed Ion Chromatogram (RIC) 28
1.3.3 Multiple Ion Detection (MID) 29
1.4 LC/MS 29
1.5 MS/MS 30
1.5.1 MS/MS by Double Focusing Instruments 30
1.5.2 MS/MS by Triple Quadrupoles 31
1.5.3 MS/MS by Ion Traps 32
1.5.4 MS/MS by Q-TOF 34
References 34
2 How to Design a Quantitative Analysis 37
2.1 General Strategy 38
2.1.1 Project 41
2.1.2 Sampling 41
2.1.3 Sample Treatment 42
2.1.4 Instrumental Analysis 43
2.1.5 Method Validation 53
References 53
3 How to Improve Specificity 55
3.1 Choice of a Suitable Chromatographic Procedure 56
3.1.1 GC/MS Measurements in Low and High Resolution Conditions 56
3.1.2 LC/ESI/MS and LC/APCI/MS Measurements 61
3.2 Choice of a Suitable Ionization Method 79
3.3 An Example of High Specificity and Selectivity Methods: The Dioxin Analysis 85
3.3.1 Use of High Resolution MID Analysis 85
3.3.2 NICI in the Analysis of Dioxins, Furans and PCBs 93
3.3.3 MS/MS in the Detection of Dioxins, Furans and PCBs 95
3.4 An Example of MALDI/MS in Quantitative Analysis of Polypeptides: Substance P 101
References 106
4 Some Thoughts on Calibration and Data Analysis 107
4.1 Calibration Designs 108
4.2 Homoscedastic and Heteroscedastic Data 108
4.2.1 Variance Model 109
4.3 Calibration Models 109
4.3.1 Unweighted Regression 109
4.3.2 Weighted Regression 119
4.3.3 A Practical Example 126
4.4 Different Approaches to Estimate Detection and Quantification Limits 130
References 132
Index 135