Horner / Rout / Rushton | Interpreting Dental Radiographs | E-Book | sack.de
E-Book

E-Book, Englisch, Band 5, 176 Seiten

Reihe: QuintEssentials of Dental Practice

Horner / Rout / Rushton Interpreting Dental Radiographs

E-Book, Englisch, Band 5, 176 Seiten

Reihe: QuintEssentials of Dental Practice

ISBN: 978-1-85097-316-4
Verlag: Quintessence Publishing Co. Ltd.
Format: EPUB
Kopierschutz: Adobe DRM (»Systemvoraussetzungen)



After clinical history-taking and examination, radiography is the "third way" of diagnosis, and dentists face the daily task of interpreting radiographic images to help in patient management. This book aims to give a comprehensive guide to reading x-ray images in dental practice and concentrates on intraoral radiographs. The text builds on a strong foundation of anatomical knowledge and is reinforced by the authors' experience of the radiological appearances that frequently challenge dentists.
Horner / Rout / Rushton Interpreting Dental Radiographs jetzt bestellen!

Weitere Infos & Material


Chapter 1 Basic Principles
Chapter 2 Normal Anatomy
Chapter 3 Dental Caries
Chapter 4 Radiology of the Periodontal Tissues
Chapter 5 Periapical and Bone Inflammation
Chapter 6 Anomalies of Teeth
Chapter 7 Trauma to the Teeth and Jaws
Chapter 8 Assessment of Roots and Unerupted Teeth
Chapter 9 Radiolucencies in the Jaws
Chapter 10 Mixed Density and Radiopapque Lesions
Index


Chapter 1
Basic Principles
Aim
The aims of this foundation chapter are threefold: first, to give an understanding of the nature of the radiographic image and the factors that govern its formation; second, to recognise the limitations of radiographs; finally, to describe a systematic approach to image interpretation. Introduction
Our eyes constantly expose our brain to “images”. Our binocular vision allows us to cope with three-dimensions while our colour vision helps to characterise the subtle variations of the objects around us. In contrast, radiographs seem to present a far simpler view on things: x-ray images are two-dimensional and consist of black, white and shades of grey. Interpretation of radiographic images, however, poses very different challenges from those presented by everyday vision. An understanding of these is essential to interpretation. What Makes the Image?
Image formation begins with a pattern of x-rays hitting the image receptor (film, intensifying screen/film combination or digital receptor). This pattern is recorded, either chemically (film) or electronically (digital radiography), and displayed as a pattern of densities. The image you see is dictated principally by three factors: the nature of the radiation the nature of the objects lying between the x-ray source and the receptor the characteristics of the image receptor. The Nature of the Radiation
X-ray energy and intensity are the important factors here. X-ray energy
X-rays are high-energy, high frequency, short wavelength electromagnetic radiation. However, “x-rays” cover a band within the electromagnetic spectrum ranging from lower energy (lower frequency, longer wavelength) to higher energy (higher frequency, shorter wavelength). How the radiation that comes out of your x-ray set fits into this range of energies depends principally upon the kilo Voltage (kV). Most modern dental x-ray sets in the UK are in the 65 to 70kV band. Previously, many sets were manufactured to operate at 50kV. While the kV affects radiation dose, in this chapter we are concerned with the radiographic image. In this context, lower kV leads to high-contrast “black and white” images with few intermediate grey tones. Relatively higher kV produces images with more subtle variation in grey tones (longer grey scale) and lower overall contrast (Fig 1-1). Fig 1-1 These images of a tooth and a small aluminium step wedge were produced at 50kV (top) and 90kV (bottom). The difference is subtle but the 50kV image shows greater contrast, seen most easily on the stepwedge. X-ray intensity
The greater the intensity of x-rays the more radiation hits the film. This produces a higher-density (“darker”) image. The Nature of the Object
The factors included in the “nature” of the objects are as follows. Atomic number
This refers to the size of the atoms. High atomic number elements absorb x-radiation very effectively (Fig 1-2). Thus, materials like gold (atomic number = 79) absorb more radiation than calcium (atomic number = 20). High atomic number elements like barium (atomic number = 56) are added to some dental materials to make them radiopaque and thus help in making them visible on radiographs. In fact, the absorption of x-rays is proportional to the cube of the atomic number (“Z3 effect”), making this an extremely potent influence on overall x-ray attenuation by materials. Fig 1-2 The most striking example of the effect of atomic number upon x-ray absorption is seen with an everyday radiograph. This bitewing shows the enormous contrast difference between metallic restorations (high atomic number) and everything else. The gold crown is very radiopaque because of its very high atomic number, while the composite restorations in a number of teeth are comparatively radiolucent. The bone and teeth (moderately high atomic number elements) are, in turn, substantially more radiopaque than areas showing soft tissues (low atomic number elements). Physical density
Atomic size is not the only factor of importance in x-ray attenuation. Physical density also plays a significant role. The most practical example of this is the contrast between air and soft tissues. While the mean atomic numbers of these are quite small, the relatively low density of air means that there is a very obvious contrast on radiographs at air/soft tissue boundaries (Fig 1-3). Fig 1-3 Air/soft tissue interfaces. Despite the fairly small difference in average atomic number between soft tissues and air, a visible contrast is present due to the large difference in density. The tongue outline is shown by white arrows, the soft palate posterior surface with black arrows. Thickness and shape
Thicker objects absorb more x-rays than thinner ones of the same material. Of course, in nature, objects are of variable thickness and usually have rounded margins. This means that in a two-dimensional radiograph the object will vary in its radiopacity according to its shape. In practice, these three factors (atomic number, density and thickness) combine to govern the absorption of x-rays. However, the radiographic image depends upon the ability of the receptor (film, intensifying screen/film combination or digital receptor) to record and display the information in the attenuated x-ray beam. The Characteristics of the Image Receptor
The important characteristics of the image receptor are: density contrast size of silver halide grains. Density and contrast are partly governed by the characteristics of the objects in the x-ray beam (atomic number, physical density and thickness, as described above) but are also profoundly influenced by the radiographic process itself. In particular, image receptors all have individual “characteristic curves”, that relate the density to the x-ray exposure. This relationship is only linear for some digital systems, all others being non-linear (Fig 1-4). The reasons for this, and the details of the curves for different image receptors, are not relevant to this book. The important point is that changing the image receptor (e.g. changing from one manufacturer of film to another) will have effects upon the character of the image you see, all other factors being equal. Fig 1-4 Characteristic curve for dental x-ray film(s). Optical density (vertical axis) indicates the “darkness” of the film. For the same density, film A requires less exposure than film B. Film A is, therefore, the faster film. The size of the silver halide grains in the emulsion has a strong influence upon the ability of a radiograph to differentiate between structures that lie close together (resolution). Resolution is objectively measured by radiographing test objects containing very fine metal wires of decreasing thickness and intervening distance. It can be expressed as the number of line pairs per millimetre (l.p. mm-1). Dental intraoral film has very high resolution – around 20 l.p.mm-1 – greater than the detail visible to the unaided human eye. This explains why magnification of intraoral (periapical, bitewing) radiographs not only increases image size but also improves the detail that can be perceived. Most intensifying screen/film cassette combinations, such as would be used for panoramic radiography, have a resolution of around 5 to 6 l.p. mm-1, explaining why radiographs produced using cassettes can never reproduce detail as well as intraoral film. The resolution of digital receptors used for intraoral radiography has been estimated at between 6 and 15 l.p. mm-1, depending on the system used. This, in part, may explain research findings that reveal that some intraoral digital systems are less effective at demonstrating fine root canal systems and fine endodontic files than conventional film. Three images of the same object on different image receptors that demonstrate resolution differences are shown in Fig 1-5. Using larger grain sizes is one way of increasing film speed. Thus, higher speed to reduce dose to patients involves a trade-off in terms of a reduction in sharpness of the image. Image sharpness is discussed in more detail below. Fig 1-5 Three radiographs of the same tooth, taken using conventional dental film (right), an intensifying screen/film cassette combination (centre) and a digital intra-oral x-ray system (left). The difference in image sharpness is obvious, with conventional dental film being best. Indeed, at this magnification the grains of this fast emulsion (F-speed) dental film are visible. How “Accurate” is a Radiographic Image?
We tend to rely a lot on radiographs in dentistry. This reliance is based upon a trust that the image represents the truth accurately. In reality, no radi-ographic image can be a perfect representation of life. Some of the factors that should be considered are: magnification image sharpness spatial perspective temporal perspective. Magnification
All conventional radiographic images are magnified. Radiographs are “shadow pictures” and the size of the shadow depends upon the relative relationship of x-ray source, object and image receptor. But we can use simple geometry (Fig 1-6) to redefine magnification as: Fig 1-6 Magnification (M) can be...


Ihre Fragen, Wünsche oder Anmerkungen
Vorname*
Nachname*
Ihre E-Mail-Adresse*
Kundennr.
Ihre Nachricht*
Lediglich mit * gekennzeichnete Felder sind Pflichtfelder.
Wenn Sie die im Kontaktformular eingegebenen Daten durch Klick auf den nachfolgenden Button übersenden, erklären Sie sich damit einverstanden, dass wir Ihr Angaben für die Beantwortung Ihrer Anfrage verwenden. Selbstverständlich werden Ihre Daten vertraulich behandelt und nicht an Dritte weitergegeben. Sie können der Verwendung Ihrer Daten jederzeit widersprechen. Das Datenhandling bei Sack Fachmedien erklären wir Ihnen in unserer Datenschutzerklärung.